  • Well. I’m not sure I fully understand it. The way I calibrated e steps was to tell it to extrude 100mm of filament and then measures how much filament was pushed through the nozzle. This resulted in a value of about 680 steps/mm.

    This always overextrudes and setting it down to 640 steps/mm made it much better.

    Setting flow rate in the slicer does not seem to have the same effect.

    Lowering e-steps gave the result I wanted but with a lower value than was calibrated for.