According to data from the Energy Information Administration (EIA), more than 20 gigawatts (GW) of battery capacity have been added to the US electric grid in the last four years. This rapid expansion is equivalent to the production of 20 nuclear reactors and is crucial for averting power disruptions, especially in states that rely significantly on intermittent renewable energy sources such as wind and solar.

  • reddig33@lemmy.world
    link
    fedilink
    arrow-up
    33
    arrow-down
    2
    ·
    6 days ago

    I’d like to see a cost comparison. I’m guessing all that battery storage cost less than the price of a nuclear reactor over its lifetime.

      • RvTV95XBeo@sh.itjust.works
        link
        fedilink
        arrow-up
        25
        arrow-down
        1
        ·
        6 days ago

        Not trying to be a “nuclear shill”, but it is worth mentioning from the article you linked:

        The 1.8 million solar panels are expected to generate up to 690 MW and they’re co-located with 380 MW of 4-hour battery energy storage (1,400 MWh).

        The capacity factor of solar is something around 25%, so that 690 MW solar array (even with batteries) produces about as much energy as ~160 MW nuclear… So 7x faster, but the costs are closer than you suggest. Solar is still cheaper because the O&M costs are minimal, but pretending 690 MW solar + 380 MW battery is equivalent to 1 GW nuclear is a bit disingenuous.

        • mosiacmango@lemm.ee
          link
          fedilink
          arrow-up
          15
          ·
          edit-2
          6 days ago

          That’s a solid critique. We can math it out more.

          So each 1.2GW reactor works out to be 17bil. Time to build still looks like 14 years, as both were started on the same time frame, and only one is fully online now, but we will give it a pass. You could argue it took 18 years, as that’s when the first proposals for the plants were formally submitted, but I only took into account financing/build time, so let’s sick with 14.

          For 17bil in nuclear, you get 1.2GW production and 1.2GW “storage” for 24hrs.

          So for 17bil in solar/battery, you get 4.8GW production, and 2.85gw storage for 4hrs. Having that huge storage in batteries is more flexible than nuclear, so you can provide that 2.85gw for 4 hr, or 1.425 for 8hrs, or 712MW for 16hrs. If we are kind to solar and say the sun is down for 12hrs out of every 24, that means the storage lines up with nuclear.

          The solar also goes up much, much faster. I don’t think a 7.5x larger solar array will take 7.5x longer to build, as it’s mostly parallel action. I would expect maybe 6 years instead of 2.

          So, worst case, instead of nuclear, for the same cost you can build solar+ battery farms that produces 4x the power, have the same steady baseline power as nuclear, that will take 1/2 as long to build.

      • EleventhHour@lemmy.world
        link
        fedilink
        arrow-up
        3
        arrow-down
        7
        ·
        edit-2
        6 days ago

        Yes, but one must also factor in the cost of the power source. Is it a solar or wind farm? Is it just off the grid? One way or another, the cost of the power source does factor into this. You know, because nuclear reactors, etc, generate power, but batteries merely store it.

    • Antitoxic9087@slrpnk.net
      link
      fedilink
      arrow-up
      3
      ·
      edit-2
      5 days ago

      Although renewable + bess still wins according to most recent studies on that matter, cost comparison between nuke and renewable / Bess is not that useful. Assumptions on the longevity of nuke reactors, for example, helps little if the fleet of reactors end up constantly break down and require repairment as in France and Belgium. So lcoe of nuke over long time span is highly uncertain and contingent; even in construction phase nuclear projects already entails higher risk in time and budget overrun than renewables. Plus the positive feedback loop of learning curve, evident in renewable and Bess, is not so visible for nuclear.

      What is more useful for sake of current policy discussion is deployment rate and scalability, which renewable plus batteries clearly wins.

  • Mihies@programming.dev
    link
    fedilink
    arrow-up
    9
    arrow-down
    21
    ·
    6 days ago

    Can we please not post such dumb articles? Like any article mentioning battery capacity in watts

    • Blair@slrpnk.netOP
      link
      fedilink
      English
      arrow-up
      9
      arrow-down
      1
      ·
      6 days ago

      Sorry! I have dyscalculia, so I’ll admit I didn’t try to analyze the numbers at all. I can delete the post

        • Mihies@programming.dev
          link
          fedilink
          arrow-up
          7
          arrow-down
          2
          ·
          6 days ago

          How can an article reliable convey information when the core measurement unit used in article is invalid? Not taking about slightly wrong numbers, but the foundation of the article.

          • humanspiral@lemmy.ca
            link
            fedilink
            arrow-up
            13
            ·
            6 days ago

            Storage does have 2 relevant metrics. how fast it can charge/discharge in GW, and the amount of energy available in gwh. Batteries typically have both these amounts equal. While other storage technologies usually can discharge a large amount of gwh at a slow rate. The discharge rate is often limited to the line capacity available as well.

            • JohnDClay@sh.itjust.works
              link
              fedilink
              arrow-up
              2
              ·
              edit-2
              6 days ago

              They’re equal if they’re running at a 1c discharge rate. Lfp, which are stable and good for safety, can have higher discharge rates of 5c up to 25c. Which would mean the capacity would be much less. To compare apples to apples, it’d be much better if they gave both the GW and GWh numbers.

              • Mihies@programming.dev
                link
                fedilink
                arrow-up
                2
                ·
                6 days ago

                Yep, the two numbers picture the actual status. What good is having a GW power if it lasts for a second, sort of speak.

              • intensely_human@lemm.ee
                link
                fedilink
                arrow-up
                2
                arrow-down
                1
                ·
                6 days ago

                No they’re equal if the battery is designed to provide 1 hr of coverage.

                A 1 GWh batter will last 1 hour if its discharge rate is 1 GW.

                It’s the timeframe of 1 hour that makes these two measures numerically equal.

                • Tobberone@lemm.ee
                  link
                  fedilink
                  arrow-up
                  1
                  ·
                  6 days ago

                  Thats what was said, for some applications 1c is good, for others 0,5 or even 0,25 is better. It depends on your usecase. Frequency regulation is often 1c, while if you are primarily concerned about depth, you could choose another configuration. It is also partly dependent on chemistry.

                  As an example: a 100kWh can be at either 1c discharge rate, or 0,5c. 50 kW(0,5c) is usually cheaper because there is less need for hardware (and I believe less risk of thermal runaway)

    • where_am_i@sh.itjust.works
      link
      fedilink
      arrow-up
      4
      ·
      6 days ago

      Welcome to the rabbit hole of energy storage.

      Turns out nobody cares about the capacity but about the discharge rate. Which is why you’ll often hear about how many Gigawatts a certain energy storage project has, and nothing about GWh.

      If you think about it for a bit, it does make sense. A lot of solutions would take days to fully discharge, so you might think “oh we have an entire city’s energy consumption for a week in some storage”, but in reality you could maybe power one neighborhood with that cuz of the discharge rate.

      So, capacity refers to the “output capacity”.